With the widespread adoption of 800V high-voltage architectures in new energy vehicles and the accelerating electrification of heavy-duty trucks and construction machinery, high-power "flash charging" and ultra-fast charging technologies are undergoing rapid, explosive evolution. Modern DC fast-charging stations, integrated solar-plus-storage charging hubs, and energy-storage-enabled charging/discharging equipment are now capable of delivering instantaneous currents reaching thousands of amperes—fundamentally transforming traditional charging and energy-replenishment paradigms. As charging speeds continue to reach new heights, capabilities such as real-time high-current acquisition, high-voltage system safety isolation, dynamic closed-loop control, and ultra-fast fault protection have become critical factors. These elements are essential for ensuring the stable operation of ultra-fast charging equipment and the safety of the battery during the charging process; they also serve as the core technical safeguards for Battery Management Systems (BMS), charger regulation, and early-warning systems for thermal runaway.
The Acrel AHKC-KA series of split-core, open-loop Hall-effect current sensors is specifically engineered for high-power industrial DC monitoring applications. Utilizing the Hall effect to achieve complete electrical isolation, these sensors are well-suited for demanding environments—such as high-power rapid charging, energy storage charge/discharge cycles, and ultra-fast charging for heavy-duty vehicles—offering five key advantages that overcome the limitations of traditional monitoring solutions.
With an ultra-wide measurement range (covering 500A to 5000A, with a 4000A model as the primary offering), these sensors are designed to withstand high-magnitude transient peak currents. They are ideally suited for high-power applications, including fast-charging stations for heavy-duty new energy vehicles, integrated solar-plus-storage inverter systems, commercial and industrial energy storage charging/discharging units, and battery pack aging test equipment. These sensors can accurately capture massive inrush currents during equipment startup while maintaining stable measurements of steady-state currents during constant-current fast-charging phases. They effectively overcome the limitations of conventional sensors—such as insufficient measurement range, magnetic core saturation, waveform distortion, and data drift—making them perfectly adapted to the dynamic current fluctuations characteristic of ultra-fast charging scenarios.
Featuring a split-core, open-type design, the AHKC-KA series offers a distinct advantage over traditional closed-core current transformers. Its detachable, split-core structure eliminates the need to disconnect main busbars, power down equipment, or dismantle power cables. The unit can be easily clamped directly onto high-capacity copper busbars, enabling rapid installation and commissioning. This significantly shortens the deployment timeline for new fast-charging cabinets and charging piles. It is particularly well-suited for retrofitting, upgrading, and maintaining existing fast-charging installations—effectively overcoming the challenges of long downtime and high operational risks typically associated with modifying legacy equipment, while substantially boosting the operational and maintenance efficiency of charging stations.
The AHKC-KA (4000A model) is specifically engineered for high-power fast-charging applications. It offers excellent parameter adaptability and high compatibility, allowing for direct integration with various fast-charging control systems. Key specifications include: a rated input of 4000A DC; a standard 5V/4V output signal, enabling direct connection to AD acquisition modules, master MCUs, or PLCs; and an auxiliary power supply of ±15V DC. The unit features a 104×36mm aperture, accommodating multiple high-power copper busbars. With a frequency bandwidth of 0–20kHz, it is well-suited for the complex, high-frequency waveforms found in fast-charging inverters. It provides an insulation withstand voltage of AC 2500V/1min, meeting isolation and protection standards for high-voltage systems. For installation, it supports both cabinet-panel mounting and DIN-rail mounting, making it ideal for the compact internal layouts of fast-charging cabinets.
Hall sensor application
1. High-power supercharging stations for new energy heavy-duty trucks and buses are installed on the main DC output circuit of charging piles. They monitor the total busbar current in real-time and, in coordination with BMS (Battery Management System) commands, perform intelligent voltage regulation—maintaining constant current or constant voltage—to achieve closed-loop control of the fast-charging process. These systems also provide overload protection, short-circuit warnings, and individual-unit energy metering, ensuring a safe and stable high-current fast-charging experience for heavy-duty vehicles.
2. Industrial and commercial solar-plus-storage "flash-charging" systems monitor high-current charge/discharge flows within the Power Conversion System (PCS). By integrating with on-site photovoltaic (PV) generation and self-consumption setups, these systems capture dynamic charge/discharge data. This enables optimized strategies for peak shaving, valley filling, and off-peak fast charging, thereby enhancing the energy efficiency and operational stability of integrated solar-plus-storage systems.
3. Aging test equipment used in power battery diagnostic laboratories facilitates high-current charge/discharge cycling tests. By recording the energy charged into and discharged from the batteries, these systems accurately replicate real-world fast-charging conditions. This allows for the verification of a battery cell’s tolerance to fast charging and its overall cycle life, providing reliable data to support battery R&D and performance testing.
4. DC busbar monitoring systems for large-scale data center UPS (Uninterruptible Power Supply) units track both the inrush current during the activation of backup power fast-charging and the steady-state operating current. By rapidly identifying current anomalies, these systems help prevent UPS overloads and short-circuit faults, ensuring the stable operation of the data center’s uninterruptible power supply infrastructure.
Split-core hall sensor dimension.

Type | Current input | Analog output | Diameter | Power supply |
AHKC-EKAS | 0~(50-500)A | 5V/4V | Φ20mm | DC ±12V/±15V |
AHKC-EKAA | DC 0~(50-500)A | DC4-20mA | Φ20mm | DC12V/24V |
AHKC-EKDA | AC 0~(50-500)A | DC4-20mA | Φ20mm | DC12V/24V |
AHKC-EKB | 0~(200-1000)A | 5V/4V | DCΦ40mm | DC ±12V/±15V |
AHKC-EKBA | DC 0~(200-1000)A | DC4-20mA | Φ40mm | DC12/24V |
AHKC-EKBDA | AC 0~(200-1000)A | DC4-20mA | Φ40mm | DC12V/24V |
AHKC-EKC | 0~(500-1500)A | 5V/4V | Φ55mm | DC ±12V/±15V |
AHKC-EKCA | DC 0~(500-1500)A | DC4-20mA | Φ55mm | DC12/24V |
AHKC-EKCDA | AC 0~(500-1500)A | DC4-20mA | Φ55mm | DC12/24V |
AHKC-K | 0~(400-2000)A | 5V/4V | 64*16mm | DC ±12V/±15V |
AHKC-KAA | DC 0~(400-2000)A | DC4-20mA | 64*16mm | DC12V/24V |
AHKC-KDA | AC 0~(400-2000)A | DC4-20mA | 64*16mm | DC12/24V |
AHKC-H | 0~(500-3000)A | 5V/4V | 82*32mm | DC ±12V/±15V |
AHKC-KA | 0~(500-5000)A | 5V/4V | 104*36mm | DC ±12V/±15V |
AHKC-HB | 0~(2000-8000)A | 5V/4V | 132*52mm | DC ±12V/±15V |
AHKC-HBAA | DC 0~(2000-8000)A | DC4-20mA | 132*52mm | DC12V/24V |
AHKC-HBDA | AC 0~(2000-8000)A | DC4-20mA | 132*52mm | DC12V/24V |