In the current economic and social development field, the development trend of digitalization and intelligence is becoming more and more obvious. Under this development trend, the data center computer room is equivalent to the role of the central nervous system. The data center computer room can provide various services to the network system. , assisting the reliable operation of each system. The main functions of the data center computer room are:
Data storage and management. The existence of this function improves the security of data information. Due to the security design in the data center computer room, the loss and leakage of some important data is effectively avoided.
Maintain the reliability and stability of the system. After the dedicated data center computer room is built, it can provide users with various services because the data center computer room has multiple functions and high-standard design.
This makes the operation of each system more stable and network services more efficient. Security protection and supervision. After the data center computer room is completed and put into use, its security factor is relatively high, which can resist hackers and virus intrusions to a certain extent. The cooperation of multiple security technologies provides users with It provides a good data network environment and builds a relatively scientific security prevention system.
The AMC series data center precision power distribution system is designed for the end of the data computer room. It is an intelligent system that can comprehensively collect all energy data, provide accurate electrical parameter information for AC and DC power distribution cabinets, and can upload data to the dynamic environment through communication. The monitoring system realizes real-time monitoring and effective management of the entire data computer room, providing a reliable guarantee for the realization of green IDC.
Telemetry: input three-phase voltage, three-phase current, active power, and active energy of the branch; output single-phase voltage, single-phase current, active power, and active energy of the branch;
Remote signaling: Overvoltage/undervoltage, phase loss, overcurrent of the input branch, switching status of the input branch and the output branch, with current and power demand analysis and statistics, and the realization of over-the-counter parameters such as voltage, current, and power. Limited alarm function.
Telemetry: input shunt voltage, current, power, and energy; Remote signaling: input the overvoltage/undervoltage of the branch, input the fuse status of the branch, have current and power demand analysis and statistics, and realize the over-limit function of voltage, current, power and other parameters.